To access the localized content, select the website associated with the Division of your interest:

Health & Safety

    Healthcare & Life Sciences

      Energy & Mobility

        • Electrostatic HME filter (HMEF) Comfort Fit, image 1

        Electrostatic HME filter (HMEF) Comfort Fit

        8866/100

        GVS offers a range of HMEF filters for use within Anesthesia, Respiratory and Critical Care clinical areas.

        Indicated for use with patients whose upper airways are being bypassed by an artificial tracheal airway or receiving artificial ventilator support.

        TDS

        Ask for information

        Properties

        HMEF retains and returns heat and moisture but also contains either a pleated or electrostatic filter media that will remove particles.

        Designed to meet the clinical requirements from the smallest baby to the largest adult, with a focus upon minimal resistance, minimum weight and product dead space, combined with the maximum possible product efficiency.

        Characteristics

        Media
        polyurethane foam
        Connections
        22M/15F - 22F/15M
        Resistance @ 30 L/min
        96 PA
        Resistance @ 60 L/min
        267 PA
        Resistance @ 90 L/min
        539 PA
        Moisture output
        11.4 mg/H2O/l @ VT 500 ml

        Applications

        • Anesthesia
        • ICU
        • Emergency
        • Homecare

        Product Variants

        Multiple versions of Electrostatic HME filter (HMEF) Comfort Fit are available.

        Product Variants

        4 available results

        1. 8866/100ABSA
          Electrostatic Filter with HME (HMEF) Bulk
          Dead Space
          76 ml
          Filtration efficiency (%)
          BFE 99.999%VFE 99.999%
          Filtration method
          Electrostatic
          Humidity Output
          29mg H2O/l @VT 500 ml
          Maximum Duration of use
          24h
          Resistance @ 30 LPM
          98pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap Luer Lock (ISO 594-1)
          Tidal Volume
          90-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 107.0 mm; w. 60.5 mm
          Filtration efficiency
          BFE 99.999%VFE 99.999%
          Housing material
          Housing Material Polypropylene
          Weight (g)
          38
        2. 8866/100BAUA
          Electrostatic Filter with HME (HMEF) clinic clean pouch packed
          Dead Space
          76 ml
          Filtration efficiency (%)
          BFE 99.999%VFE 99.999%
          Filtration method
          Electrostatic
          Humidity Output
          29mg H2O/l @VT 500 ml
          Maximum Duration of use
          24h
          Resistance @ 30 LPM
          98pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap Luer Lock (ISO 594-1)
          Tidal Volume
          90-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 107.0 mm; w. 60.5 mm
          Filtration efficiency
          BFE 99.999%VFE 99.999%
          Housing material
          Housing Material Polypropylene
          Weight (g)
          38
        3. 8866/100BRSA
          Electrostatic Filter with HME (HMEF) clinic clean blister packed
          Dead Space
          76 ml
          Filtration efficiency (%)
          BFE 99.999%VFE 99.999%
          Filtration method
          Electrostatic
          Humidity Output
          29mg H2O/l @VT 500 ml
          Maximum Duration of use
          24h
          Resistance @ 30 LPM
          98pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap Luer Lock (ISO 594-1)
          Tidal Volume
          90-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 107.0 mm; w. 60.5 mm
          Filtration efficiency
          BFE 99.999%VFE 99.999%
          Housing material
          Housing Material Polypropylene
          Weight (g)
          38
        4. 8866/100BSSA
          Electrostatic Filter with HME (HMEF) sterile pouch packed
          Dead Space
          76 ml
          Filtration efficiency (%)
          BFE 99.999%VFE 99.999%
          Filtration method
          Electrostatic
          Humidity Output
          29mg H2O/l @VT 500 ml
          Maximum Duration of use
          24h
          Resistance @ 30 LPM
          98pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap Luer Lock (ISO 594-1)
          Tidal Volume
          90-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 107.0 mm; w. 60.5 mm
          Filtration efficiency
          BFE 99.999%VFE 99.999%
          Housing material
          Housing Material Polypropylene
          Weight (g)
          38