To access the localized content, select the website associated with the Division of your interest:

Health & Safety

    Healthcare & Life Sciences

      Energy & Mobility

        • Electrostatic MIDI-HME with sampling port, image 1

        Electrostatic MIDI-HME with sampling port

        9064/711

        GVS HME acts in a similar way to a person’s upper airway, when they breathe out the media traps and retains moisture and warmth present in the expired breath, which otherwise would be lost.

        On the next breath the moisture and heat is released, having the effect of both warming and humidifying the inspiratory gas.

        TDS

        Ask for information

        Properties

        This filter type contains a polyurethane foam which retains and returns heat and moisture to the patient.

         

        Characteristics

        Media
        Polyurethane Foam
        Connections
        22M/15F - 22F/15M
        Resistance @ 30 L/min
        129 PA
        Resistance @ 60 L/min
        305 PA
        Resistance @ 90 L/min
        542 PA
        Moisture output
        34 mg/H2 O/l @VT 500 m

        Applications

        • Anesthesia
        • ICU
        • Emergency
        • Homecare

        Product Variants

        Multiple versions of Electrostatic MIDI-HME with sampling port are available.

        Product Variants

        4 available results

        1. 9064/711ABSA
          Electrostatic Filter with Heat Moisture Exchanger (HMEF) Bulk Packed
          Dead Space
          35 ml
          Filtration efficiency (%)
          BFE 99.9996%, VFE 99.9992%
          Filtration method
          Electrostatic HMEF
          Maximum duration of use
          24h
          Resistance @ 30L/min
          118 Pa
          Tidal Volume
          120-1500 ml
          Box quantity
          350
          Connection inlet
          22M/15F - 22F/15M
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          green polypropylene
          Weight (g)
          19.6
        2. 9064/711BAUA
          Electrostatic Filter with Heat Moisture Exchanger (HMEF) Clinic Clean pouch packed
          Dead Space
          35 ml
          Filtration efficiency (%)
          BFE 99.9996%, VFE 99.9992%
          Filtration method
          Electrostatic HMEF
          Maximum duration of use
          24h
          Resistance @ 30 LPM
          118 Pa
          Tidal Volume
          120-1500 ml
          Box quantity
          200
          Connection inlet
          22M/15F - 22F/15M
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          green polypropylene
          Weight (g)
          19.6
        3. 9064/711BRSA
          Electrostatic Filter with Heat Moisture Exchanger (HMEF) Clinic Clean blister packed
          Dead Space
          35 ml
          Filtration efficiency
          BFE 99.9996%, VFE 99.9992%
          Filtration method
          Electrostatic HMEF
          Maximum duration of use
          24h
          Resistance @ 30 LPM
          118 Pa
          Tidal Volume
          120-1500 ml
          Box quantity
          50
          Connection inlet
          22M/15F - 22F/15M
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Filtration efficiency
          BFE 99.9996%, VFE 99.9992%
          Housing material
          green polypropylene
          Weight (g)
          19.6
        4. 9064/711BSSA
          Electrostatic Filter with Heat Moisture Exchanger (HMEF) Sterile blister packed
          Dead Space
          35 ml
          Filtration efficiency (%)
          BFE 99.9996%, VFE 99.9992%
          Filtration method
          Electrostatic HMEF
          Maximum duration of use
          24h
          Resistance @ 30L/min
          118 Pa
          Tidal Volume
          120-1500 ml
          Box quantity
          50
          Connection inlet
          22M/15F - 22F/15M
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          green polypropylene
          Weight (g)
          19.6

        This website uses first-party and third-party cookies in order to offer dynamic content and a better user experience. For further information please read our Privacy Policy.