To access the localized content, select the website associated with the Division of your interest:

Health & Safety

    Healthcare & Life Sciences

      Energy & Mobility

        • HME with sampling port, image 1

        HME with sampling port

        4333/751

        GVS HME acts in a similar way to a person’s upper airway, when they breathe out the media traps and retains moisture and warmth present in the expired breath, which otherwise would be lost.

        On the next breath the moisture and heat is released, having the effect of both warming and humidifying the inspiratory gas.

        TDS

        Ask for information

        Property

        This filter type contains a polyurethane foam which retains and returns heat and moisture to the patient.

        Characteristics and Advantages

        Weight
        27 gr
        Filter media
        Polyurethane foam

        Applications

        • Anesthesia
        • ICU
        • Emergency
        • Homecare

        Product Variants

        Multiple versions of HME with sampling port are available.

        Product Variants

        4 available results

        1. 4333/751ABSA
          Heat Moisture Exchanger (HME) Bulk Packed
          Dead Space
          53 ml
          Filtration efficiency (%)
          Not Applicable
          Humidity Output
          31mg/H2O @ VT 500 ml
          Maximum Duration of use
          24h
          Note of Filtration Efficiency
          Independently tested, data available upon request*
          Resistance @ 60 LPM
          180 pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          150-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 77.0 mm; w. 68.5 mm
          Filtration efficiency
          Not Applicable
          Housing material
          Transparent Polypropylene
          Notes
          Product is available without a luer lock gas sampling port as code 4333/752BRSA clinic clean blistered packed
          Weight (g)
          27
        2. 4333/751BAUA
          Heat Moisture Exchanger (HME) Clinic Clean pouch packed
          Dead Space
          53 ml
          Filtration efficiency (%)
          Not Applicable
          Humidity Output
          31mg/H2O @ VT 500 ml
          Maximum Duration of use
          24h
          Note of Filtration Efficiency
          Independently tested, data available upon request*
          Resistance @ 60 LPM
          180 pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          150-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 77.0 mm; w. 68.5 mm
          Filtration efficiency
          Not Applicable
          Housing material
          Transparent Polypropylene
          Notes
          Product is available without a luer lock gas sampling port as code 4333/752BRSA clinic clean blistered packed
          Weight (g)
          27
        3. 4333/751BRSA
          Heat Moisture Exchanger (HME) Clinic Clean blister packed
          Dead Space
          53 ml
          Filtration efficiency (%)
          Not Applicable
          Humidity Output
          31mg/H2O @ VT 500 ml
          Maximum Duration of use
          24h
          Note of Filtration Efficiency
          Independently tested, data available upon request*
          Resistance @ 60 LPM
          180 pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          150-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 77.0 mm; w. 68.5 mm
          Filtration efficiency
          Not Applicable
          Housing material
          Transparent Polypropylene
          Notes
          Product is available without a luer lock gas sampling port as code 4333/752BRSA clinic clean blistered packed
          Weight (g)
          27
        4. 4333/751BSSA
          Heat Moisture Exchanger (HME) Sterile blister packed
          Dead Space
          53 ml
          Filtration efficiency (%)
          Not Applicable
          Humidity Output
          31mg/H2O @ VT 500 ml
          Maximum Duration of use
          24h
          Note of Filtration Efficiency
          Independently tested, data available upon request*
          Resistance @ 60 LPM
          180 pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          150-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 77.0 mm; w. 68.5 mm
          Filtration efficiency
          Not Applicable
          Housing material
          Transparent Polypropylene
          Notes
          Product is available without a luer lock gas sampling port as code 4333/752BRSA clinic clean blistered packed
          Weight (g)
          27

        This website uses first-party and third-party cookies in order to offer dynamic content and a better user experience. For further information please read our Privacy Policy.