        • Small MIDI HME with sampling port, image 1

        Small MIDI HME with sampling port

        9064/751

        GVS HME acts in a similar way to a person’s upper airway, when they breathe out the media traps and retains moisture and warmth present in the expired breath, which otherwise would be lost.

        On the next breath the moisture and heat is released, having the effect of both warming and humidifying the inspiratory gas.

        TDS

        Ask for information

        Property

        This filter type contains a polyurethane foam which retains and returns heat and moisture to the patient.

        Characteristics and Advantages

        Filter media
        Polyurethane foam
        Connections
        22M/15F - 22F/15M
        Resistance @ 30 L/min
        92 PA
        Resistance @ 60 L/min
        255 PA
        Resistance @ 90 L/min
        501 PA
        Moisture output
        34 mg/H2O/l a VT 500 ml

        Applications

        • Anesthesia
        • ICU
        • Emergency
        • Homecare

        Product Variants

        Multiple versions of Small MIDI HME with sampling port are available.

        Product Variants

        3 available results

        1. 9064/751ABSA
          Heat Moisture Exchanger (HME) Bulk Packed
          Dead Space
          34 ml
          Humidity Output
          31mgH2O/l @VT 500 ml *
          Maximum Duration of use
          24h
          Note of Humidity Output
          Independently tested, data available upon request
          Resistance @ 30 LPM
          23pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          120-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          Transparent Polypropylene, HME material, Polyurethane foam
          Weight (g)
          21
        2. 9064/751BRSA
          Heat Moisture Exchanger (HME) Clinic Clean blister packed
          Dead Space
          34 ml
          Humidity Output
          31mgH2O/l @VT 500 ml *
          Maximum Duration of use
          24h
          Note of Humidity Output
          Independently tested, data available upon request
          Resistance @ 30 LPM
          23pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          120-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          Transparent Polypropylene, HME material, Polyurethane foam
          Weight (g)
          21
        3. 9064/751BSSA
          Heat Moisture Exchanger (HME) Sterile blister packed
          Dead Space
          34 ml
          Humidity Output
          31mgH2O/l @VT 500 ml *
          Maximum Duration of use
          24h
          Note of Humidity Output
          Independently tested, data available upon request
          Resistance @ 30 LPM
          23pa
          Sampling port Luer Lock (ISO 594-1)
          Gas monitoring luer port with retainer strap
          Tidal Volume
          120-1500 ml
          Box quantity
          50
          Connection inlet
          Connections (ISO 5356-1)
          Dimension
          h. 81.4 mm; w. 48.1 mm
          Housing material
          Transparent Polypropylene, HME material, Polyurethane foam
          Weight (g)
          21