To access the localized content, select the website associated with the Division of your interest:

Health & Safety

    Healthcare & Life Sciences

      Energy & Mobility

        • Blood Tubular Filters Hemodialysis, image 1
        • Blood Tubular Filters Hemodialysis, image 2
        • Blood Tubular Filters Hemodialysis, image 3
        • Blood Tubular Filters Hemodialysis, image 4
        • Blood Tubular Filters Hemodialysis, image 5

        Blood Tubular Filters Hemodialysis

        Mesh and Tubular filters manufactured by GVS are especially dedicated to the transfusion market but they can easily meet the requirements of many other different applications.

        Most important are:

        - blood filters for transfusion drip chambers;
        - blood filters for hemodialysis drip chambers;
        - high volume liquid filters for general purpose applications.

        Ask for information

        Property

        Thanks to the wide choice of sizes and wide variety of materials and media used, GVS tubular filters are compatible with most existing or new devices. Available mesh sizes are from 1 to 500 µm as well as membranes are available from 0.2µm to 5µm.

        GVS mesh and tubular filters are manufactured according to ISO1135 standard.

        They are manufactured following the ISO9001 and ISO13485 standards, in class 100.000 cleanrooms with medical grade materials (plastics and mesh/membrane), and pass USP plastics class VI and ISO10993 tests for biocompatibility (standard for external communicating device – blood path indirect – prolonged contact duration).

        They have low extractable levels and wide drug compatibility.

        They are non-pyrogenic (<0.25 EU/ml) using the LAL test method, and they are latex free, PVC free and free of animal origin substances

        Characteristics

        Efficiency of filtration
        98%
        Pyrogenicity
        <0.25 Eu/ml
        Maximum Operating Temperature
        50°C

        Applications

        • Hemodialysis

        Product Variants

        Multiple versions of Blood Tubular Filters Hemodialysis are available.

        Product Variants

        15 available results

        1. FI089AAKUN040A00
          Tubular Filter FI89, Clear PA6, Mesh PA6.6 40µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          7.00
          Filter material
          Mesh PA6.6
          Housing material
          PA6
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          40
          Open area (%)
          31
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          5.60
          Socket OD (mm)
          13.50
          Total Height (mm)
          32.30
        2. FI110PPNY200
          Tubular Filter FI110, Clear PP, Mesh PP 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8.000
          Effective filtration area (cm²)
          9.00
          Filter material
          Mesh PA6.6
          Housing material
          PP
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          8.00
          Socket OD (mm)
          16.21
          Total Height (mm)
          38.43
        3. FI110PPNY263
          Tubular Filter FI110, Clear PP, Mesh PA6.6 263µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8.000
          Effective filtration area (cm²)
          9.00
          Filter material
          Mesh PA6.6
          Housing material
          PP
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          263
          Open area (%)
          47
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          8.00
          Socket OD (mm)
          16.21
          Total Height (mm)
          38.43
        4. FI116ATERP265A00
          Tubular Filter FI116, Clear ABS, Mesh PE 265µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8000
          Effective filtration area (cm²)
          10.5
          Filter material
          Mesh PE
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          265
          Open area (%)
          53
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 1135-4 / ISO 8638
          Socket H (mm)
          4.05
          Socket OD (mm)
          16.42
          Total Height (mm)
          40.95
        5. FI116AV29N170A00
          Tubular Filter FI116, Clear PP, Mesh PA6.6 170µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8000
          Effective filtration area (cm²)
          10.5
          Filter material
          Mesh PA6.6
          Housing material
          PP
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          170
          Open area (%)
          42
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          4.05
          Socket OD (mm)
          16.42
          Total Height (mm)
          40.95
        6. FI118APURP200A00
          Tubular Filter FI118, Clear PE, Mesh PE 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          6.00
          Filter material
          Mesh PE
          Housing material
          PE
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          4.00
          Socket OD (mm)
          16.33
          Total Height (mm)
          24.40
        7. FI118ATEKP150B00
          Tubular Filter FI118, White ABS, Mesh PE 150µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          6.00
          Filter material
          Mesh PE
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          150
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          4.00
          Socket OD (mm)
          16.33
          Total Height (mm)
          24.40
        8. FI118TERNY263
          Tubular Filter FI118, Clear ABS, Mesh PA6.6 263µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          6.00
          Filter material
          Mesh PA6.6
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          263
          Open area (%)
          47
          Ref. standard
          ISO 8638
          Socket H (mm)
          4.00
          Socket OD (mm)
          16.33
          Total Height (mm)
          24.40
        9. FI157ATEKN263B01
          Tubular Filter FI157, White ABS, Mesh PA6.6 263µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10000
          Effective filtration area (cm²)
          6.0
          Filter material
          Mesh PA6.6
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          263
          Open area (%)
          47
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          8.00
          Socket OD (mm)
          17.43
          Total Height (mm)
          28.40
        10. FI158TERNY200
          Tubular Filter FI158, Clear ABS, Mesh PA6.6 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          15.000
          Effective filtration area (cm²)
          6.00
          Filter material
          Mesh PA6.6
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          3.44
          Socket OD (mm)
          15.74
          Total Height (mm)
          23.85
        11. FI231ACOLP200A00
          Tubular Filter FI231, Clear PVC soft DEHPC - free, Mesh PE 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8.000
          Effective filtration area (cm²)
          5.60
          Filter material
          Mesh PE
          Housing material
          PVC soft DEHPC - free
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 10933-11
          Socket H (mm)
          7.97
          Socket OD (mm)
          15.40
          Total Height (mm)
          28.50
        12. FI231PVCPE200
          Tubular Filter FI231, Clear PVC, Mesh PE 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          8000
          Effective filtration area (cm²)
          5.60
          Filter material
          Mesh PE
          Housing material
          PVC soft
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 10933-1
          Socket H (mm)
          7.97
          Socket OD (mm)
          15.4
          Total Height (mm)
          28.5
        13. FI83ABSPE150
          Tubular Filter FI83, White ABS, Mesh PE 150µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          7.000
          Effective filtration area (cm²)
          8.20
          Filter material
          Mesh PE
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          150
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          9.80
          Socket OD (mm)
          17.52
          Total Height (mm)
          39.20
        14. FI89TERNY200
          Tubular Filter FI89, Clear ABS, Mesh PA6.6 200µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          7.00
          Filter material
          Mesh PA6.6
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          200
          Open area (%)
          43
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          5.60
          Socket O
          13.50 mm
          Total Height (mm)
          32.30
        15. FI89TERNY300
          Tubular Filter FI89, Clear ABS, Mesh PA6.6 300µm
          Filtration Efficiency
          98%
          Assembly method
          Interference
          Box quantity
          10.000
          Effective filtration area (cm²)
          7.00
          Filter material
          Mesh PA6.6
          Housing material
          ABS
          Maximum operating temperature
          50°C
          Mesh opening (µm)
          300
          Open area (%)
          51
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 8638
          Socket H (mm)
          5.60
          Socket OD (mm)
          13.50
          Total Height (mm)
          32.30