        • Priming Filters, image 1
        • Priming Filters, image 2
        • Priming Filters, image 3

        Priming Filters

        Air elimination is an important feature for an air vent.

        Air elimination really depends on the effective filtration area and on the pore size of the membrane used.

        Air Flow is one of the key characteristics that should be considered when choosing an air vent.

        Ask for information

        Properties

        GVS air vents are complied with the ISO 10993 standard for external communicating devices - blood path indirect - prolonged contact duration.

        Characteristics

        Ref. Standard
        ISO 8536-4
        Efficiency of Filtration
        100%
        Pyrogenicity
        < 0.25 EU/ml
        Maximum Operating Temperature
        50°C

        Applications

        • Infusion

        Product Variants

        Multiple versions of Priming Filters are available.

        Product Variants

        3 available results

        1. TA225BV29G002D01
          TA225 - Priming Filter in Blue PP, 0.2µm PVDF - ISO 80369-7
          Air flow
          >10 ml/min @153 cm H2O
          Assembly method
          Interference
          Box quantity
          50.000
          Effective filtration area
          0.107 cm²
          Filter material
          PVDF
          Housing material
          PP
          Outside diameter
          Female Luer Lock
          Pore size (µm)
          0.2
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 80369-7
          Temperature
          50°C
          Total Height (mm)
          18.60
          Water breakthrough
          0.5 bar for 5 minutes
        2. TA225BV29G012D01
          TA225 - Priming Filter in Blue PP, 1.2µm PVDF - ISO 80369-7
          Air flow
          40 ml/min @ 20 cm H20
          Assembly method
          Interference
          Box quantity
          50.000
          Effective filtration area
          0.107 cm²
          Filter material
          PVDF
          Housing material
          PP
          Outside diameter
          Female Luer Lock
          Pore size (µm)
          1.2
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 80369-7
          Temperature
          50°C
          Total Height (mm)
          18.6
          Water breakthrough
          0.177 bar for 15 minutes
        3. TA240AV29G002F00
          TA240 - Priming Filter in Yellow PP, 0.2µm PVDF - ISO 80369-6
          Air flow
          >3.47 ml/min @153 cm H2O
          Assembly method
          Interference
          Box quantity
          50.000
          Effective filtration area
          0.107 cm²
          Filter material
          PVDF
          Housing material
          PP
          Outside diameter
          Female Neuraxial
          Pore size (µm)
          0.2
          Pyrogenicity EU/ml
          <0.25
          Ref. standard
          ISO 80369-6
          Temperature
          50°C
          Total Height (mm)
          18.00
          Water breakthrough
          0.5 bar for 5 minutes