          Sterility test canister

            💡 For product specifications, applications and ordering information, please refer to the attached catalogue.

          Catalog (ordering info)

          Ask for information

          Property

          Gamma sterilization

          • Assembled clamps for pipelines are more convenient to use

          • Double-layer aseptic packaging facilitates the transfer in the clean

          room and reduces the pollution during the transfer process

          • Gamma ray sterilization, no residue, safe and reliable, avoiding the appearance of false negative results

          • SAL≤10-6

          • Ultrasonic welding process ensures tightness and pressure resistance

          • 100% passed the airtight performance test

          • Microbial retention, microbial growth (sensitivity) and sterility testing ensure that the results of sterility testing are authentic and reliable

          • Filter membrane: bubble point method, bacterial retention rate test

          • Sterility test 14 day

           EO sterilization

          • Adopt composite film packaging technology, good air permeability and bacteria resistance

          • Ultrasonic welding process is adopted to ensure tightness and pressure resistance

          • The pipe is equipped with a stop clip, which is convenient for customers to operate and improve efficiency

          • The pump tube is made of composite materials imported from Germany, with higtihc iteyl aasnd tension Durable, wear and pressure resistant, can ensure the maximum amount of filtr a on successfully completed accomplished

          • Filter membrane: bubble point method, bacterial retention rate test

          • 100% passed the sealing performance test

          • Using advanced gamma ray sterilization, no residue, safe and reliable, avoiding the occurrence of false negative results; SAL ≤10*

          • Aseptic independent packaging, and double-layer packaging mode, so that through the buffer zone into the aseptic room, to achieve rapid detection

          • Through microbial retention, microbial growth promotion (sensitivity) and sterility test, to ensure that the sterility test results are authentic and reliable

          • Sterility test: 14-day culture cycle, consistent with pharmacopoeia requirements

          Characteristics

          Cup material
          AS
          Bottom material
          ABS
          Filter membrane material
          MCE/Nylon/PP 0.45μm
          Cup volume
          100ml
          Filter material
          PTFE diameter 25mm, 0.45μm